Acquire data from Carescape B850, Solar, Dash and Telemetry Central over the Unity Network®. The MDP2040-0100 provides performance and economy.

Vital Signs Displayable

  • Heart Rate + 3 leads of ECG + PVC count
  • ST values
  • Non-Invasive Blood Pressure
  • Invasive Blood Pressures: (up to 4 multi-patient, up to 6 surgical)
  • Pulse Oximetry
  • Respiration
  • Temperature
  • Capnography
  • Arrhythmias and messages

 

Applications

(Performs in all patient care areas)

  • Telemetry
  • Emergency Room and Step Down
  • PREOP and OR
  • Post Anesthesia Care Units
  • Gastro-Intestinal Endoscopy Departments
  • ICU and CCU
  • Special Procedures: Cardiac Cath Labs, EP Labs

Features

  • HIPAA compliant
  • Provides visual and audible alarms
  • Displays up to nine waveforms per patient
  • Monitor patients in 1, 4, 6, 8, 12 and 16 patient format
  • Print on alarm, tabular and graphical trends
  • Field Upgradeable
  • Updates with Admits and Discharges

Single Bed Display

Single Bed Display

Twelve Bed Display

Sixteen Bed Display

The MDP2040-0100 with GE Unity network connection provides display of all available vital signs, messages and these additional features:

 

Multi-Patient Monitoring

For CCU, ICU, PACU and Telemetry. Locate displays at Nurse’s Station, Hallways, Nurse’s Lounge or wherever monitoring coverage is desired.

 

Single Patient Monitoring

For Surgery, Emergency and Special Procedures. Single patient selection also provides these additional items: Stop watch timer, ECG1 Freeze, Common or Separate baseline, 02, BIS and two Gas values.

 

Single Patient Temporary Display

When monitoring multiple beds, a single-bed can be selected for full-screen viewing of all available parameters for that patient. The multiple-patient display will resume after one minute or by pressing the ESC button. If a different bed goes into alarm while in full- screen view, a flashing message will notify the user that another bed is in alarm.

Patient Alarms

Visual alarms & audible alarms duplicate the GE patient monitor sound.

 

Print

When the Print function is selected, this menu will appear:

 

Menu Item Description
Real-Time Prints 12 seconds history, 4 seconds real time, preceded by 1 hour trend
Tab Prints tabular trend
Graph Prints graphic trend
Print on Crisis When enabled, a Real-time page is automatically printed upon a CRISIS alarm type as defined from the patient monitor. Printer must be enabled within Setup Menu and Alarm Response must be set to ALL or CRISIS in the Service menu.

 

Real-Time Print

Tabular Print

Graphic Trend Print

MDP2040-0100 Network Activity

The MDP2040-0100 operates with independent configurability. It builds bed/patient lists by listening for Rwhat packets, and allows the user to select up to 16 different beds/patients for display.

 

Some common questions with answers are presented below:

 

How does the MDP gather data to display?

The MDP listens on the GE Unity Network for Rwhat ID packets to build a list of available Beds/Patients being monitored. With no patients selected on the MDP for display, the MDP is completely silent, with no Network traffic being output at all. When beds are selected for viewing, the MDP must output Numeric and Waveform Request packets that are just over 100 bytes each in size to each bed being monitored.

 

How much traffic will the MDP add?

Outputs: Rwhats-0. The MDP does not output any Rwhat identifying packets. Numeric Requests-1 numeric request packet / 3 seconds for each displayed bed. Wave Requests- 1 wave request/stimulation packet every 10-15 seconds for each displayed bed to keep the waves coming continuously.

 

Does the MDP add any vulnerable points to the network?

Our Ethernet interface is a 10 Base-T network. The user can set the IP to maintain complete control over device IP address assignment. The MDP’s NIC chip has built-in hardware for anti-jabber detection to terminate transmission. The MDP is not PC based and uses no OS that is vulnerable to viruses or external concerns usually addressed by employing Fire Walls.

 

What is involved with installing/setting up your system onto a network?

A typical installation may include an Ethernet connection to GE’s network switches.

 

Installation: If a network connection is installed in the location where NetViewer is to be located, connect via a non-crossover Cat5 cable between NetViewer and the network connection. (If the MDP is to be connected directly to the patient monitor then a crossover cable is required.) Connect a Video monitor into NetViewer. Apply power to NetViewer and Video monitor. Allow several seconds to acquire Patient Monitor list. Using the supplied control ( Remote Knob or Mouse), select a Bed/Patient to monitor. One or up to 16 Patients can be selected.

 

Patient Monitor Setup: Each GE monitor must be setup with a ‘Care Area’ and ‘Bed ID’ before access over the Network is possible. This is done under the SERVICE menu of the Patient Monitor. If the Patient Monitors are already connected to a GE Server or CIC, this has already been done.

MDP2040-0100 Front View

Front View

MDP2040-0100 Rear View

Rear View

Specifications

GE Unity Network Compatible

Models: Carescape B850 and B650, Solar, Dash, Eagle, Telemetry

Display

Colors:

Time Base:

13 available for selection

25mm/sec or 50mm/sec

CO2 and RESP fixed at 6.25 mm/sec in 1 and 4 patient formats

Formats

1, 4, 6, 8, 12 or 16 beds

Vital Signs

Waveforms: 3 ECGs, 6 INVPs, SPO2, RESP, CO2
Numeric Values:

HR or PR, INVP Sys/Dias/Mean, NIBP, ST, PVC, SpO2/PR,

EtCO2/InCO2, O2, BIS, GAS, CO/BT, Resp/Breath Rate and Temp

Visual Alarms

Parameter Limit Violations:

Current Alarm Level:

Arrhythmia Messages:

Flashing Red value(s) if displayed or flashing Red parameter name(s) if not displayed

Patient/Info bar: Sys-Warning=Yellow Advisory=Flash White Warning=Flash Yellow Crisis=Flash Red

Displayed in red

Audible Alarms

Audible Suspend:

Audible Alarm Levels:

Volume Control:

Internal Speaker:

Administrator Control:

3 minutes

Reproduces GE’s Crisis, Warning, Advisory, and System Warning alert sounds

8 Volume settings

Internal speaker provides sound. An external speaker is optional.

All alarm settings, Selected Priority Levels, Volume, and enables require Administrative Password

Control

Hand Held Remote and/or Mouse

Printing

Graphic Trend:

Tabular Trend:

Alarm or Manual:

Plot of 8 hr. numeric value history sampled every 2 min

8 hr. of numeric values sampled every 2 min

Prints provide 16 second snapshots, 12 seconds of which are history

Video Output

Analog RGB:

Sync:

0.7 Vpp, 75 ohms

TTL Negative going

Resolutions:

1280x1024 (4:3)

1680x1050 (16:10)

1920x1080 (16:9)

Horizontal Rate

63.8 kHz

65.4 kHz

67.1 kHz

Vertical Rate

60.0 Hz

60.0 Hz

60.0 Hz

Physical

Size:

MDP2040-0100

H 1.5” (38 mm)

W 7.8” (198 mm)

D 8.2” (208 mm)

Power Adapter

5V @2A. Certified to be in compliance with the Electrical Safety and

Environmental standards listed below. 100-240V, .38A@100V, .24A@240V.

Weight:
1.7 lbs. (0.77 kg)

AC Input

100-240V, .38A @ 100V, .24A @ 240V

Electrical Safety

Conforms to IEC 60601-1 as Class 1 device; Listed for UL60601-1

Environmental

Temperature:

Operating

0 to 40° C

Storage

-40 to +85° C

Humidity:

5% to 95%, non-condensing

EMC

IEC 60601-1-2:2007 Class B. CISPR 11:2009 (Amended by A1:2010)

 

FDA

Device 510K listed

CE/Medical Device Directive

CB Scheme testing, CE marking per Medical Device Directive, Directive 2007/47/EC Class IIb Device.

Quality Certification

VIDCO Inc. is certified to the ISO13485 Quality Standard